How To Install A 220 Outlet In Garage
Garages are not what they used to be. Some people apply them to store their vehicles and nothing else. Just others utilize their garages as work stations, extra bedrooms, additional sitting rooms, laundry rooms, and so much more. As a upshot, the placement of your outlets volition depend on the purpose the garage serves.
What Peak Should Garage Outlets Be?
Almost people position their wall outlets between 12 and 18 inches above the finished flooring in well-nigh rooms. But, there is no specific height requirement for garage outlets. Technically speaking, the garage is just another room. As such, you tin apply this trend to your garage without suffering whatsoever significant consequences.
What is The NEC Code For Garage Outlet Peak?
The National Electric Code doesn't have anything to say about the height of electrical outlets in a garage or whatever other room in a dwelling. For that reason, you are technically free to identify your garage outlets at any height that suits you.
Many contractors place outlets 12 to eighteen inches in a higher place the floor because that summit suits nearly people, not because the NEC demands it.
That being said, the American Disabilities Act expects homeowners to place wall receptacles at least fifteen inches to a higher place the floor. The goal is to make the receptacles in question easier to access for disabled persons. But that only applies to spaces in a edifice that are intended for use by the occupants of that building.
If your garage doesn't fit that description, you lot don't take to follow the garage outlet height proffer of the American Disabilities Act. That beingness said, before you lot mount an outlet in a garage, bank check your local code. It might have something to say about the height of garage outlets.
You should also consider the purpose the garage will serve. For instance, if you want to install a woodworking workstation, the superlative of the outlets should friction match the height of the countertops and workstations.
Outlet Acme In Garage
Electrical Particular | Pinnacle |
Refrigerator & Deep Freezer | 48 inches |
Water Heater | 18 inches |
Washer & Dryer | 34-36 inches |
Grit Control | 15-20 inches |
Table Press | 15-20 inches |
Drill Press | thirty-36 inches |
- Related Postal service What Is The Standard Top For A Fridge Outlet?
Where Should Outlets Exist Placed In the Garage?
The NEC doesn't specify a particular location where the garage wall outlet should be mounted. Many people endeavor to place one receptacle on each sidewall.
The position of a wall outlet in a garage doesn't thing. Or at the very least, the NEC doesn't take anything to say on the effect. Check your local code to determine whether or not information technology has a regulation that governs the position of garage wall outlets. If you have countertops and workstations in the garage, the outlet should exist within range of the appliances and machines you want to operate. That includes fridges, washing machines, and drills.
Types of Outlets That Should Be Used In A Garage
The blazon of work you want to do in your garage will determine the types of outlets yous will install. For instance:
1). 15A 120V Outlets
Nigh garages use standard 15A, 120 Volt outlets. They are suitable for most situations, specially if yous want to operate conventional devices such every bit televisions, speakers, and computers that practice not eat a lot of power.
2). 20A 125V Outlets
20A, 125V outlets are normally paired with devices that consume more than power than the standard 15A 120V outlet tin handle, such as large kitchen appliances. They are perfect for garages that are supposed to double as laundry rooms. If you want your garage to house washing machines and infinite heaters, I expect you lot to install 20A 125V outlets.
3). 20A 250V Outlets
Many people think that they need 20A, 250V outlets for fridges, freezers, and washing machines. But as y'all now know, those appliances tin can run on 20A 125V outlets. 20A 250V outlets are only relevant to homeowners that want to operate high-powered tools like plasma cutters, grinders, sanders, and drills. You also need higher-gauge wiring to prevent the breaker from tripping whenever you employ your tools.
4). GFCI Outlets
I desire homeowners to add GFCI outlets to their garages. This is because garages are exposed to moisture. Rain can slip through the garage doors. If it comes in contact with your tools, a catastrophe could occur. This is why GFCI outlets are so of import. Y'all don't take a selection in the matter.
The NEC expects homeowners to utilise GFCI protection to all outlets in a garage. You can merely ignore this regulation if your local code contradicts it. The local code supersedes the NEC. Merely the local code in most areas tends to agree with the NEC, at to the lowest degree where garage outlets are concerned.
How Many Outlets Are Required In A Garage?
The NEC expects homeowners to install a minimum of one wall outlet in a given garage. Just you can install more than ane if the need arises. At the end of the day, your situation will inform the number of outlets you have. For instance, you have to identify a refrigerator on a dedicated circuit.
As such, if you want to add a refrigerator too as a workstation with a power tool, yous need at least two outlets; one for the refrigerator and one for the ability tool.
Garage Outlet Spacing Code
Co-ordinate to United states of america National Electrical Code, department 210.52 of the NEC expects homeowners to install a wall outlet every vi feet in every habitable room. You can apply this code to a garage if yous have any intention of using information technology equally a living room, bedroom, kitchen, bathroom, pantry, and laundry room.
Otherwise, it doesn't count as a habitable room, in which instance, the NEC doesn't have anything to say most the space betwixt garage outlets. Your local code might address the event, which is why yous should consult information technology.
How Far Apart Should Outlets Exist Spaced?
In a habitable room, every betoken forth the wall should be no more six feet from an outlet. The regulation doesn't utilize to garages. Even so, you tin can adapt it for your garage all the same because it makes sense. It ensures that you have an outlet inside accomplish of any appliance you want to employ. That way, you lot are less likely to employ ability strips and extension cords.
Source: https://portablepowerguides.com/garage-outlet-height-and-spacing/